APC NetShelter Basic Rack PDU, 1U, 1PH, 3.7kW 230V 16A or 3.3kW 208V 16A, x12 C13 Outlets, C20 Cord PDU
In stock
APC NetShelter Metered Rack PDU, 0U, 1PH, 3.3kW 208V 16A or 3.7kW 230V 16A, 18 C13 and 2 C19 outlets, C20 inlet PDU
In stock
APC NetShelter Metered Rack PDU, 0U, 1PH, 3.7kW 230V 16A, x18 C13 and x2 C19 outlets, IEC 309 cord PDU
In stock
APC NetShelter Metered Rack PDU, 0U, 1PH, 7.4kW 230V 32A, 36 C13 and 6 C19 outlets, IEC 309 2P+E cord PDU
In stock
APC NetShelter Metered Rack PDU, 0U, 3PH, 11kW 230V 16A or 11kW 230V 16A, 36 C13 and 6 C19 outlets, IEC 309 3P+N+PE cord PDU
In stock
APC NetShelter Metered Rack PDU, 2U, 1PH, 7.4kW 230V 32A, x12 C13 and x4 C19 outlets, IEC 309 cord PDU
In stock
APC NetShelter Metered Rack PDU, 2U, 1PH, 7.4kW 230V 32A, x12 C13 and x4 C19 outlets, IEC 309 cord PDU
In stock
APC NetShelter Metered-by-Outlet Rack PDU, 0U, 1PH, 7.4kW 230V 32A, x21 C13 and x3 C19 Outlets, IEC 309 Cord PDU
In stock
APC NetShelter Rack PDU Advanced, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309
In stock
Description
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2″ wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today’s high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
Specifications
| Lead time | Usually in Stock |
|---|
| Colour | Black |
|---|---|
| Product or component type | PDU |
| PDU type | Switched |
| Cord length | 1.8 m |
| Input Voltage | 415 V 3 phases 400 V 3 phases |
|---|---|
| Height | 178.0 cm |
| Width | 5.6 cm |
| Output Voltage | 240 V |
| Depth | 7.5 cm |
| Net weight | 9.6 kg |
| Mounting location | Side |
| Mounting preference | No preference |
| Input Plug Type | IEC 60309 30 A 3P + N + PE |
| Mounting mode | Rack-mounted |
| Rack units | 0U |
| Mounting position | Vertical |
| Communication port protocol | 1000BASE-T 10/100BASE-T |
| [In] rated current | 24 A |
| Permissible voltage | 200…240 V 346…415 V |
| Input current limits | 30 A |
| Load capacity | 17300 VA |
| Network frequency | 50/60 Hz |
| Outlet type and quantity | 24 C13/C15/C19/C21 24C13/C15 |
| Product certifications | UKCA TAA compliance BAA compliance |
|---|---|
| Standards | UL 62368-1 CSA C22.2 No 62368-1 FCC part 15 Subpart B CE EN 62368-1 |
| IP degree of protection | IP44 |
| Ambient air temperature for operation | -5…60 °C |
| Relative humidity | 5…95 % |
| Operating altitude | 0…10000 ft |
| Ambient air temperature for storage | -25…65 °C |
| Storage Relative Humidity | 5…95 % |
| Storage altitude | 0.0000000000…15240.0000000000 m |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 198 cm |
| Package 1 Width | 13.2 cm |
| Package 1 Length | 26.2 cm |
| Package 1 Weight | 12.6 kg |
| Warranty | 3 years repair or replace |
|---|
APC NetShelter Switched Rack PDU, 1U, 1PH, 2.3kW 230V 10A or 2.5kW 208V 12A, 8 C13 Outlets, C14 cord PDU
In stock
APC NetShelter Switched Rack PDU, 1U, 1PH, 3.7kW 230V 16A or 3.3kW 208V 16A, 8 C13 Outlets, C20 Cord PDU
In stock
APC Rack PDU 2G, Metered by Outlet with Switching, Zero U, 32A, 230V, (21) C13 & (3) C19 PDU
In stock